Investigating hiatal hernia (HH) size reporting, researchers compared subjective estimates with objective axial length measurements in 93 patients. While endoscopic subjective size allocations correlated with intra-operative decisions, axial length measurements significantly correlated with manometry results. Only one barium swallow report included an objective HH size measurement. Integrating axial length measurements into endoscopy reports is crucial, enhancing outcome precision and informing clinical decisions, emphasizing the need to move beyond subjective terms in HH characterization.

Journal Article by Palenzuela DL, Gee D (…) Paranjape C et 3 al. in Surg Endosc

© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.