High Recurrence Rates in Contaminated Hernia Repair with Bio-A Mesh

Researchers evaluated the long-term outcomes of using bio-A biosynthetic mesh in ventral hernia repairs, finding a 17.4% overall recurrence rate. Contaminated cases had a higher recurrence rate of 28.8% compared to 10.4% in clean cases. Despite this, the study confirms the cost-effective use of biosynthetic mesh in all wound classifications, with good outcomes, limited long-term complications, and low recurrence rates.

Journal Article by Huang EY, Broderick RC (…) Jacobsen GR et 6 al. in Surg Endosc

© 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.